Hello, welcome to visit Wuxi Security Monitoring, Wuxi Monitoring, Wuxi Remote Monitoring, and the official website of Wuxi Dehang Technology Co., Ltd!

 1512008412106430.png   Service hotline 138-618-32237

 Wuxi Monitoring

technical support

Product classification

contact us

Enterprise name: Wuxi Dehang Technology Co., Ltd

Contact: Mr. Liu

Tel.: 0510-68289990

Mobile: 13861832237

Email: [email protected]

Website: nabenjixie.cn

Address: Room 1202, No. 99 Zhaoshangcheng Road, Wuxi, Jiangsu

Welcome to Wuxi Security Monitoring, Wuxi Monitoring, Wuxi Remote Monitoring - the official website of Wuxi Dehang Technology Co., Ltd!

Classification and application of camera protective cover Wuxi Surveillance

Classification and application of camera protective cover Wuxi Surveillance

Date of issue: 2019-01-05 Author: Click:

Wuxi Monitoring , monitoring video camera According to the different places of use, the protective covers can be divided into indoor type and outdoor type. Here is a brief introduction to the two types.

1、 Indoor protective cover
The indoor protective cover must be able to protect the camera and lens from the pollution of dust, impurities and corrosive gases. At the same time, it must be able to cooperate with the installation site to prevent damage. Indoor enclosure is generally made of painted or anodized aluminum, painted steel, brass or plastic. If plastic is used, fire-resistant or flame retardant type shall be used. The protective cover must have sufficient strength, the installation interface must be firm, and the window should be clear and transparent safety glass or plastic (polycarbonate). The design position of electrical connection interface shall be convenient for installation and maintenance.

The working temperature of the camera is - 5 ℃~45 ℃, and the most appropriate temperature is 0 ℃~30 ℃, otherwise the image quality will be affected, or even the camera will be damaged.

2、 Outdoor protective cover
First of all, the outdoor protective cover should be highly sealed to prevent rainwater from entering. At the same time, the inlet shall be opened below the protective cover to avoid rainwater flowing into the protective cover along the cable. A wiper shall also be installed in front of the protective cover to timely clean the accumulated rainwater and dirt, so that the camera can take a clear image through the glass. The defroster in front of the hood or on the glass can melt the frost and snow in the window.

Secondly, a heater should be installed in the protective cover to heat in a low temperature environment, improve the internal temperature of the protective cover, and ensure the normal operation of the camera/lens; The internal or external fan can make the air in the cover circulate and reduce the temperature in the protective cover; In places with more sand and less rain, it is also necessary to consider configuring a washer to clean the window glass with the wiper at any time to ensure the image monitoring effect.

The auxiliary equipment control function of the outdoor protective cover includes automatic control and manual control. For example, the heater/defroster and fan are automatically started or closed by the temperature sensor inside the protective cover, while actions such as wiper and washer are realized by the controller through the operation of the control equipment.

The outdoor enclosure is generally made of aluminum, coated steel, stainless steel or plastic that can be used in outdoor environment. The manufacturing materials must be able to withstand ultraviolet radiation, or they will soon appear cracks, fading, strength reduction and other aging phenomena. Stainless steel shield shall be used in the environment where it is required to be durable, with high safety, and resistant to human destruction; The properly treated aluminum shield is also a shield with excellent performance. There are three treatment methods: polyurethane baking paint, anodic oxidation, and anodic oxidation plus painting. Aluminum or steel mutual aid should not be selected in the environment with corrosive gas; Shields made of stainless steel or special plastic shall be used in salt spray environment. In addition, in order to increase the safety performance of the protective cover and prevent man-made damage, many protective covers are also equipped with tamper proof switches. Once the protective cover is opened, an alarm signal will be sent out. There are many kinds of protective covers in the monitoring system, which can be generally divided into rectangular cover, wall or ceiling cover, spherical cover, corner cover, slope cover, etc. according to their shapes.


Website: //nabenjixie.cn/news/383.html

key word: Wuxi remote monitoring , Wuxi Monitoring Project , Wuxi remote monitoring

Recent browsing:

  • Online Service
  • contact number
    thirteen billion eight hundred and sixty-one million eight hundred and thirty-two thousand two hundred and thirty-seven
  • Online Message
  • Mobile website
  • Online consultation
    Welcome to leave us a message
    Please enter your message here, and we will contact you as soon as possible.
    full name
    contacts
    Telephone
    Landline/mobile number
    mailbox
    mailbox
    address
    address